Products
Research Areas
COVID-19
Resources
Login
Quick Order
Cart Cart lightblue
Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Contact Us

Location


Corporate Headquarters

Vector Laboratories, Inc.
6737 Mowry Ave
Newark, CA 94560
United States

Telephone Numbers



Customer Service: (800) 227-6666 / (650) 697-3600


Contact Us



Additional Contact Details

Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Catalog Number Size Price
LS-C782498-100 100 µg (1 mg/ml) $574 
POU2F2 / OCT2 Antibody - IHC testing of FFPE human tonsil with OCT-2 antibody (clone OCT2/2137). HIER: boil tissue sections in pH6, 10mM citrate buffer, for 10-20 min followed by cooling at RT for 20 min.
POU2F2 / OCT2 Antibody - IHC testing of FFPE human lymph node with OCT-2 antibody (clone OCT2/2137). HIER: boil tissue sections in pH6, 10mM citrate buffer, for 10-20 min followed by cooling at RT for 20 min.
POU2F2 / OCT2 Antibody - Analysis of HuProt(TM) microarray containing more than 19,000 full-length human proteins using OCT-2 antibody (clone OCT2/2137). These results demonstrate the foremost specificity of the OCT2/2137 mAb. Z- and S- score: The Z-score represents the strength of a signal that an antibody (in combination with a fluorescently-tagged anti-IgG secondary Ab) produces when binding to a particular protein on the HuProt(TM) array. Z-scores are described in units of standard deviations (SDs) above the mean value of all signals generated on that array. If the targets on the HuProt(TM) are arranged in descending order of the Z-score, the S-score is the difference (also in units of SDs) between the Z-scores. The S-score therefore represents the relative target specificity of an Ab to its intended target.
POU2F2 / OCT2 Antibody - Western blot testing of 1) partial recombinant protein and 2) human Daudi lysate with OCT-2 antibody (clone OCT2/2137). Expected molecular weight: isoforms from 43~62 kDa.
POU2F2 / OCT2 Antibody - Western blot testing of human Ramos lysate with OCT-2 antibody (clone OCT2/2137). Expected molecular weight: isoforms from 43~62 kDa.
POU2F2 / OCT2 Antibody - SDS-PAGE analysis of purified, BSA-free OCT-2 antibody (clone OCT2/2137) as confirmation of integrity and purity.
POU2F2 / OCT2 Antibody - IHC testing of FFPE human tonsil with OCT-2 antibody (clone OCT2/2137). HIER: boil tissue sections in pH6, 10mM citrate buffer, for 10-20 min followed by cooling at RT for 20 min.
POU2F2 / OCT2 Antibody - IHC testing of FFPE human lymph node with OCT-2 antibody (clone OCT2/2137). HIER: boil tissue sections in pH6, 10mM citrate buffer, for 10-20 min followed by cooling at RT for 20 min.
POU2F2 / OCT2 Antibody - Analysis of HuProt(TM) microarray containing more than 19,000 full-length human proteins using OCT-2 antibody (clone OCT2/2137). These results demonstrate the foremost specificity of the OCT2/2137 mAb. Z- and S- score: The Z-score represents the strength of a signal that an antibody (in combination with a fluorescently-tagged anti-IgG secondary Ab) produces when binding to a particular protein on the HuProt(TM) array. Z-scores are described in units of standard deviations (SDs) above the mean value of all signals generated on that array. If the targets on the HuProt(TM) are arranged in descending order of the Z-score, the S-score is the difference (also in units of SDs) between the Z-scores. The S-score therefore represents the relative target specificity of an Ab to its intended target.
POU2F2 / OCT2 Antibody - Western blot testing of 1) partial recombinant protein and 2) human Daudi lysate with OCT-2 antibody (clone OCT2/2137). Expected molecular weight: isoforms from 43~62 kDa.
POU2F2 / OCT2 Antibody - Western blot testing of human Ramos lysate with OCT-2 antibody (clone OCT2/2137). Expected molecular weight: isoforms from 43~62 kDa.
POU2F2 / OCT2 Antibody - SDS-PAGE analysis of purified, BSA-free OCT-2 antibody (clone OCT2/2137) as confirmation of integrity and purity.
1 of 6
2 of 6
3 of 6
4 of 6
5 of 6
6 of 6

Monoclonal Mouse anti‑Human POU2F2 / OCT2 Antibody (clone OCT2/2137, Azide‑free,BSA‑free, IHC, WB) LS‑C782498

Monoclonal Mouse anti‑Human POU2F2 / OCT2 Antibody (clone OCT2/2137, Azide‑free,BSA‑free, IHC, WB) LS‑C782498

Antibody:
POU2F2 / OCT2 Mouse anti-Human Monoclonal (Azide-free, BSA-free) (OCT2/2137) Antibody
Application:
IHC-P, WB, ELISA
Reactivity:
Human
Format:
Unconjugated, Azide-free, BSA-free
Price
Catalog Number
$574
LS-C782498-100
Toll Free North America
(800) 227-6666
For Research Use Only

Overview

Antibody:
POU2F2 / OCT2 Mouse anti-Human Monoclonal (Azide-free, BSA-free) (OCT2/2137) Antibody
Application:
IHC-P, WB, ELISA
Reactivity:
Human
Format:
Unconjugated, Azide-free, BSA-free

Specifications

Description
OCT2 antibody LS-C782498 is an unconjugated mouse monoclonal antibody to human OCT2 (POU2F2). Validated for ELISA, IHC and WB.
Target
Human POU2F2 / OCT2
Synonyms
POU2F2 | Homeobox protein | Oct-2 | OCT2 | Octamer-binding protein 2 | OTF-2 | OTF2 | POU class 2 homeobox 2 | Octamer-binding Transcription Factor 2 | POU domain, class 2, transcription factor 2
Host
Mouse
Reactivity
Human (tested or 100% immunogen sequence identity)
Clonality
IgG1,k Monoclonal
Clone
OCT2/2137
Conjugations
Unconjugated
Purification
Protein G affinity chromatography
Modifications
Azide-free, BSA-free
Immunogen
A portion of amino acids 112-297 from the human protein was used as the immunogen for the OCT-2 antibody.
Specificity
This antibody has been extensively validated, including cross-reactivity testing against 19,000 full-length proteins by HuProt(TM) microarray analysis.
Applications
  • IHC - Paraffin (1 - 2 µg/ml)
  • Western blot (1 - 2 µg/ml)
  • ELISA (2 - 4 µg/ml)
Performing IHC? See our complete line of Immunohistochemistry Reagents including antigen retrieval solutions, blocking agents ABC Detection Kits and polymers, biotinylated secondary antibodies, substrates and more.
Usage
Optimal dilution of the OCT-2 antibody should be determined by the researcher.
Presentation
1X PBS
Storage
Aliquot and store at -20°C.
Restrictions
For research use only. Intended for use by laboratory professionals.
Guarantee
This antibody carries the LSBio 100% Guarantee.
LSBio Guarantee
About POU2F2 / OCT2
P09086 NM_002698 NP_002689.1

Publications (0)

Customer Reviews (0)


Request SDS/MSDS

To request an SDS/MSDS form for this product, please contact our Technical Support department at:

Technical.Support@LSBio.com

Requested From: United States
Date Requested: 12/22/2024