Products
Research Areas
COVID-19
Resources
Login
Quick Order
Cart Cart lightblue
Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Contact Us

Location


Corporate Headquarters

Vector Laboratories, Inc.
6737 Mowry Ave
Newark, CA 94560
United States

Telephone Numbers



Customer Service: (800) 227-6666 / (650) 697-3600


Contact Us



Additional Contact Details

Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Catalog Number Size Price
LS-C662537-10 10 µg $318 
LS-C662537-100 100 µg $470 
NRXN1 / Neurexin 1 Antibody - Western blot analysis of Neurexin 1 using anti-Neurexin 1 antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions. Lane 1: human U-87MG whole cell lysates, Lane 2: human SHG-4 whole cell lysates. After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-Neurexin 1 antigen affinity purified polyclonal antibody at 0.5 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for Neurexin 1 at approximately 170KD. The expected band size for Neurexin 1 is at 162KD.
NRXN1 / Neurexin 1 Antibody - Western blot - Anti-Neurexin 1 antibody
NRXN1 / Neurexin 1 Antibody - Flow Cytometry analysis of U251 cells using anti-NRXN1 antibody. Overlay histogram showing U251 cells stained with anti-NRXN1 antibody (Blue line). The cells were blocked with 10% normal goat serum. And then incubated with rabbit anti-NRXN1 Antibody (1µg/10E6 cells) for 30 min at 20°C. DyLight®488 conjugated goat anti-rabbit IgG (5-10µg/10E6 cells) was used as secondary antibody for 30 minutes at 20°C. Isotype control antibody (Green line) was rabbit IgG (1µg/10E6 cells) used under the same conditions. Unlabelled sample (Red line) was also used as a control.
NRXN1 / Neurexin 1 Antibody - Western blot analysis of Neurexin 1 using anti-Neurexin 1 antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions. Lane 1: human U-87MG whole cell lysates, Lane 2: human SHG-4 whole cell lysates. After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-Neurexin 1 antigen affinity purified polyclonal antibody at 0.5 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for Neurexin 1 at approximately 170KD. The expected band size for Neurexin 1 is at 162KD.
NRXN1 / Neurexin 1 Antibody - Western blot - Anti-Neurexin 1 antibody
NRXN1 / Neurexin 1 Antibody - Flow Cytometry analysis of U251 cells using anti-NRXN1 antibody. Overlay histogram showing U251 cells stained with anti-NRXN1 antibody (Blue line). The cells were blocked with 10% normal goat serum. And then incubated with rabbit anti-NRXN1 Antibody (1µg/10E6 cells) for 30 min at 20°C. DyLight®488 conjugated goat anti-rabbit IgG (5-10µg/10E6 cells) was used as secondary antibody for 30 minutes at 20°C. Isotype control antibody (Green line) was rabbit IgG (1µg/10E6 cells) used under the same conditions. Unlabelled sample (Red line) was also used as a control.
1 of 3
2 of 3
3 of 3

Polyclonal Rabbit anti‑Human NRXN1 / Neurexin 1 Antibody (IHC, WB) LS‑C662537

Polyclonal Rabbit anti‑Human NRXN1 / Neurexin 1 Antibody (IHC, WB) LS‑C662537

Antibody:
NRXN1 / Neurexin 1 Rabbit anti-Human Polyclonal Antibody
Application:
IHC, ICC, WB, Flo, ELISA
Reactivity:
Human
Format:
Unconjugated, Unmodified
Price
Catalog Number
$318
LS-C662537-10
Toll Free North America
(800) 227-6666
For Research Use Only

Overview

Antibody:
NRXN1 / Neurexin 1 Rabbit anti-Human Polyclonal Antibody
Application:
IHC, ICC, WB, Flo, ELISA
Reactivity:
Human
Format:
Unconjugated, Unmodified

Specifications

Description
Neurexin 1 antibody LS-C662537 is an unconjugated rabbit polyclonal antibody to human Neurexin 1 (NRXN1). Validated for ELISA, Flow, ICC, IHC and WB.
Target
Human NRXN1 / Neurexin 1
Synonyms
NRXN1 | Hs.22998 | KIAA0578 | Neurexin I-alpha | Neurexin-1-alpha | PTHSL2 | Neurexin 1 | Neurexin I-beta | Neurexin I | Neurexin-1-beta | SCZD17
Host
Rabbit
Reactivity
Human (tested or 100% immunogen sequence identity)
Clonality
Polyclonal
Conjugations
Unconjugated
Modifications
Unmodified
Immunogen
E. coli-derived human Neurexin 1 recombinant protein (Position: D141-E294).
Applications
  • IHC
  • ICC
  • Western blot
  • Flow Cytometry
  • ELISA
Performing IHC? See our complete line of Immunohistochemistry Reagents including antigen retrieval solutions, blocking agents ABC Detection Kits and polymers, biotinylated secondary antibodies, substrates and more.
Presentation
Lyophilized from 0.2mg Na2HPO4, 0.9mg NaCl, 0.05mg sodium azide, 4mg Trehalose
Reconstitution
Add 0.2ml of distilled water will yield a concentration of 500µg/ml.
Storage
At -20°C for 1 year. After reconstitution, at 4°C for 1 month. It can also be aliquotted and stored frozen at -20°C for a longer time. Avoid freeze-thaw cycles.
Restrictions
For research use only. Intended for use by laboratory professionals.
Guarantee
This antibody carries the LSBio 100% Guarantee.
LSBio Guarantee
About NRXN1 / Neurexin 1
Q9ULB1 NM_004801 NP_004792.1

Publications (0)

Customer Reviews (0)


Request SDS/MSDS

To request an SDS/MSDS form for this product, please contact our Technical Support department at:

Technical.Support@LSBio.com

Requested From: United States
Date Requested: 11/25/2024