Products
Research Areas
COVID-19
Resources
Login
Quick Order
Cart Cart lightblue
Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Contact Us

Location


Corporate Headquarters

Vector Laboratories, Inc.
6737 Mowry Ave
Newark, CA 94560
United States

Telephone Numbers



Customer Service: (800) 227-6666 / (650) 697-3600


Contact Us



Additional Contact Details

Login
Registration enables users to use special features of this website, such as past
order histories, retained contact details for faster checkout, review submissions, and special promotions.


Fields marked with a * are required.

Login
Quick Order
Catalog Number Size Price
LS-B11115-200 200 µl $460 
NKX3-1 Antibody - Anti-NKX3-1 antibody IHC staining of human kidney. Immunohistochemistry of formalin-fixed, paraffin-embedded tissue after heat-induced antigen retrieval. Antibody dilution 1:100.
NKX3-1 Antibody - Western blot of NKX3-1 Antibody in MCF-7 cell line lysates (35 ug/lane). NKX3-1 (arrow) was detected using the purified antibody.
NKX3-1 Antibody - NKX3-1 Antibody flow cytometry of MDA-MB231 cells (bottom histogram) compared to a negative control cell (top histogram). FITC-conjugated goat-anti-rabbit secondary antibodies were used for the analysis.
NKX3-1 Antibody - Anti-NKX3-1 antibody IHC staining of human kidney. Immunohistochemistry of formalin-fixed, paraffin-embedded tissue after heat-induced antigen retrieval. Antibody dilution 1:100.
NKX3-1 Antibody - Western blot of NKX3-1 Antibody in MCF-7 cell line lysates (35 ug/lane). NKX3-1 (arrow) was detected using the purified antibody.
NKX3-1 Antibody - NKX3-1 Antibody flow cytometry of MDA-MB231 cells (bottom histogram) compared to a negative control cell (top histogram). FITC-conjugated goat-anti-rabbit secondary antibodies were used for the analysis.
1 of 3
2 of 3
3 of 3

IHC‑plus™ Polyclonal Rabbit anti‑Human NKX3‑1 Antibody (aa118‑145, IHC, WB) LS‑B11115

IHC‑plus™ Polyclonal Rabbit anti‑Human NKX3‑1 Antibody (aa118‑145, IHC, WB) LS‑B11115

Note: This antibody replaces LS-C164899
Antibody:
NKX3-1 Rabbit anti-Human Polyclonal (aa118-145) Antibody
Application:
IHC, IHC-P, WB, Flo
Reactivity:
Human
Format:
Unconjugated, Unmodified
Price
Catalog Number
$460
LS-B11115-200
Toll Free North America
(800) 227-6666
For Research Use Only

Overview

Antibody:
NKX3-1 Rabbit anti-Human Polyclonal (aa118-145) Antibody
Application:
IHC, IHC-P, WB, Flo
Reactivity:
Human
Format:
Unconjugated, Unmodified

Specifications

Description
NKX3-1 antibody LS-B11115 is an unconjugated rabbit polyclonal antibody to human NKX3-1 (aa118-145). Validated for Flow, IHC and WB. Tested on 20 paraffin-embedded human tissues.
Target
Human NKX3-1
Synonyms
NKX3-1 | BAPX2 | NK homeobox, family 3, A | NK3 homeobox 1 | NKX3 | NKX3.1 | Homeobox protein Nkx-3.1 | NKX3A
Host
Rabbit
Reactivity
Human (tested or 100% immunogen sequence identity)
Predicted
Mouse (at least 90% immunogen sequence identity)
Clonality
Polyclonal
Conjugations
Unconjugated
Purification
Protein A purified
Modifications
Unmodified
Epitope
aa118-145
Specificity
This NKX3-1 antibody is generated from rabbits immunized with a KLH conjugated synthetic peptide between 118-145 amino acids from the Central region of human NKX3-1.
Applications
  • IHC
  • IHC - Paraffin (1:100)
  • Western blot (1:1000)
  • Flow Cytometry (1:10 - 1:50)
Performing IHC? See our complete line of Immunohistochemistry Reagents including antigen retrieval solutions, blocking agents ABC Detection Kits and polymers, biotinylated secondary antibodies, substrates and more.
Presentation
PBS, 0.09% Sodium Azide
Storage
Maintain refrigerated at 2°C to 8°C for up to 6 months. For long term storage store at -20°C.
Restrictions
For research use only. Intended for use by laboratory professionals.
Guarantee
This antibody carries the LSBio 100% Guarantee.
LSBio Guarantee
About NKX3-1
Q99801 NM_006167 NP_006158.2

Validation

NKX3-1 Antibody - Anti-NKX3-1 antibody IHC staining of human kidney. Immunohistochemistry of formalin-fixed, paraffin-embedded tissue after heat-induced antigen retrieval. Antibody dilution 1:100.
Anti-NKX3-1 antibody IHC staining of human kidney. Immunohistochemistry of formalin-fixed, paraffin-embedded tissue after heat-induced antigen retrieval. Antibody dilution 1:100.
Anti-NKX3-1 antibody IHC staining of human kidney. Immunohistochemistry of formalin-fixed, paraffin-embedded tissue after heat-induced antigen retrieval. Antibody dilution 1:100.

LSBio Ratings

IHC-plus™ NKX3-1 Antibody (aa118-145) for IHC, WB/Western, Flow LS-B11115 has an LSBio Rating of
Laboratory Validation Score (4)

Publications (0)

Customer Reviews (0)


Request SDS/MSDS

To request an SDS/MSDS form for this product, please contact our Technical Support department at:

Technical.Support@LSBio.com

Requested From: United States
Date Requested: 12/21/2024